The Backflow Testers of Westminster

Backflow Preventer Repair in Westminster

Manufacturer parts. Retest included.

Relief valve discharge, failed checks and leaking bonnets are the top three repairs. We use the kit for your exact model, rebuild and retest before we leave.

Same-week visits. Price before any work.

Call (714) 844-5915

or book online

  • PriceFree quote
  • Time1–2 hours
  • RetestIncluded
  • ApprovalPrice first

Common fixes

  • Tired springs
  • Cracked test cocks
  • Fouled or worn check seats
  • Leaking vacuum breaker caps
  • Relief valves that spit or dump

Fixing a reduced pressure assembly

When an RP starts leaking from the relief port, people often assume the relief valve is bad. Usually it's the first check. Grit or a hardened disc lets pressure build between the checks, and the relief valve opens to protect the supply.

The repair typically means cleaning the first check seat and installing new rubber parts. If the relief valve diaphragm has a tear or its seat is damaged, that gets rebuilt too.

We retest the whole assembly afterward and file the passing report. If water keeps discharging even after a rebuild, it can point to pressure swings in the supply, and we'll tell you what we think is going on.

Fixing a double check that won't hold

A double check that fails its test almost always has one check valve that won't close tight. Debris and worn rubber are the usual suspects, the same as with an RP.

The repair involves shutting off the water, removing the check valve covers, pulling out each check module and cleaning or rebuilding it. Springs are replaced if they've lost tension. Then everything goes back together with new o-rings.

Double checks on fire lines need extra care. Shutting one down affects the sprinkler system, so we coordinate with you before starting and keep the downtime short. Once repaired, the device is retested and the report is filed.

Fixing vacuum breakers on sprinklers

Vacuum breakers on irrigation lines see a lot of sun and weather, so their rubber parts wear faster than devices tucked inside a building. Common problems include water spraying from the bonnet, a check valve that won't seal and an air inlet that sticks.

Most PVB and SVB repairs use a rebuild kit with a new check disc, air inlet poppet and o-rings. If the bonnet is cracked from freezing or sun damage, we replace it.

These repairs are usually quick, and the device is retested right after. If the device is old and parts are hard to find, replacing it can sometimes cost about the same as rebuilding it, and we'll lay out both options.

Matching the right parts to your device

Backflow preventers in Westminster come from a handful of major manufacturers, and each make and model takes its own repair parts. We carry kits for the devices we see most often and order the rest from suppliers.

Using the manufacturer's parts matters. Mixing parts from different devices can lead to a device that passes once and fails again soon after. Before we order anything, we confirm the make, model, size and serial number.

If parts aren't on the truck, we'll tell you how long they'll take to arrive and schedule a return visit. Most come in within a few days. Every repair is followed by a full retest so the district gets a passing report.

Signs your preventer needs attention

You don't always have to wait for a failed test to know something's wrong. Water dripping or spraying from an RP relief port, water spitting from the top of a PVB, a steady leak at a fitting, or a sudden drop in water pressure downstream are all signs worth a call.

Catching these early often means a simpler, cheaper repair than waiting until the device fails outright.

Repairs on fire line devices

Repairing a fire line device takes a bit more coordination. Shutting it down affects the sprinkler system, so the alarm company or building staff may need a heads-up.

We plan the work with you and keep the downtime short. These devices are often 4 inches or larger, and you'll get a quote before any work begins.

Repair visits and scheduling

Repairs often happen right after a failed test, on the same visit. If you need time to decide or get approval, we'll leave the quote with you and come back when you're ready.

Did someone else fail your device? Forward their report. The readings show us which parts to bring, which usually means a single visit.

Repair or replace

Usually yes. If the body is cracked or parts are gone, we'll go over replacement.

Questions

How long do repairs last?

A good rebuild often lasts years. Debris in the water is the main thing that shortens it.

Do you use original parts?

Yes. We use the manufacturer's repair kits for your make and model.

Which brands do you repair?

The common ones: Watts, Febco, Wilkins and Ames, plus most others we can get parts for.

Why does my preventer keep failing?

Debris in the line and age are the usual reasons. We'll tell you if replacing it makes more sense.

Is the relief valve always the problem when an RP leaks?

Usually not. Most of the time the first check is fouled or worn, and the relief valve is doing its job.

Do I need a new test after a repair?

Yes, and it's included. The district only accepts a passing test after the repair.

Where we offer it

We provide backflow preventer repair in Westminster, Midway City, Stanton, Garden Grove, Fountain Valley and Cypress. Typical wait: under a week.

Why Westminster customers call us

Certified testers, calibrated gauges and district filing on every job. You get the price before any work and a copy of every report.

Testing is $105 per device under 4 inches and $175 for 4 inches and up. Other work is quoted free. Phones are answered 7 days a week, 6am to midnight, and emergency calls 24/7. Most visits are booked within the week.

A typical visit in Westminster: a confirmation call the day before, under an hour on site for the test, and the report filed the same day. When a test fails, the fix is usually a rebuild kit, done in one to two hours with the retest included. Bigger jobs like replacements and new installs get a free written quote first. Every report we file is also emailed to you, so your records stay complete.

$105 tests. Same-week visits.

Westminster, Midway City, Stanton and nearby. Filing included.

Call (714) 844-5915

or book online